Oscilloscopes

TeledyneLecroy has a broad category of oscilloscopes to cater measurement challenges of wide range of industries and research institutes.Below is a brief description of various oscilloscope categories available and their series.

Teledyne LeCroy DSO Product Range Bandwidth Input Channels Resolution Max Sampling Rate Memory
WaveJet Touch Oscilloscopes 350 MHz - 500 MHz 4 8-bit 2 GS/s 5 Mpts
WaveSurfer 3000 Oscilloscopes 200 MHz - 750 MHz 2, 4 8-bit 4 GS/s 10 Mpts
WaveSurfer 10 Oscilloscope 1 GHz 4 8-bit 10 GS/s 16 Mpts - 32 Mpts
HDO8000 High Definition Oscilloscopes 350 MHz - 1 GHz 8 12-bit 2.5 GS/s 50 Mpts - 250 Mpts
Motor Drive Power Analysis Software   8 12-bit 2 GS/s 250 Mpts/Ch
LabMaster 10-100Zi 100 GHz Oscilloscope 100 GHz 4 to 80 8-bit 160 GS/s 20 Mpts - 1024 Mpts
WaveAce 1000 and 2000 Oscilloscopes 40 MHz - 300 MHz 2, 4 8-bit 2 GS/s 12 kpts - 1 Mpts
WaveAce 100 and 200 Oscilloscopes 40 MHz - 200 MHz 2, 4 8-bit 2 GS/s 4 kpts - 20 kpts
WaveJet 300A Oscilloscopes 100 MHz - 500 MHz  2, 4 8-bit 2 GS/s 500 kpts
WaveSurfer MXs-B and MSO MXs-B Oscilloscopes 200 MHz - 1 GHz 4 8-bit 10 GS/s 16 Mpts - 32 Mpts
HDO4000 / HDO4000-MS High Definition Oscilloscopes 200 MHz - 1 GHz 2, 4 12-bit 2.5 GS/s 12.5 Mpts - 25 Mpts
WaveRunner 6 Zi Oscilloscopes 400 MHz - 4 GHz 4 8-bit 40 GS/s 16 Mpts - 64 Mpts
HDO6000 / HDO6000-MS High Definition Oscilloscopes 350 MHz - 1 GHz 4 12-bit 2.5 GS/s 50 Mpts - 250 Mptss
HDO8000 High Definition Oscilloscopes 350 MHz - 1 GHz 12-bit 2.5 GS/s 50 Mpts - 250 Mpts
HRO 12-bit Oscilloscopes 400 MHz - 600 MHz 12-bit 2 GS/s 64 Mpts - 256 Mpts
DDA 7 Zi-A Disk Drive Analyzers 3.5 GHz - 6 GHz 8-bit 40 GS/s 32 Mpts - 256 Mpts
SDA 7 Zi-A Serial Data Analyzers 2.5 GHz - 6 GHz 8-bit 40 GS/s 32 Mpts - 256 Mpts
WavePro 7 Zi-A Oscilloscopes 1.5 GHz - 6 GHz 8-bit 40 GS/s 20 Mpts - 256 Mpts
DDA 8 Zi-A Disk Drive Analyzers 8 GHz - 30 GHz 8-bit 80 GS/s 32 Mpts - 512 Mpts
SDA 8 Zi-A Serial Data Analyzers 4 GHz - 30 GHz 8-bit 120 GS/s 32 Mpts - 768 Mpts
WaveMaster 8 Zi-A Oscilloscopes 4 GHz - 30 GHz 8-bit 120 GS/s 20 Mpts - 768 Mpts
LabMaster 9 Zi-A Oscilloscopes 13 GHz - 30 GHz 4 to 80 8-bit 120 GS/s 20 Mpts - 768 Mpts
LabMaster 10 Zi Oscilloscopes 20 GHz - 65 GHz 4  to 80 8-bit 160 GS/s 20 Mpts - 1024 Mpts
WaveExpert Sampling Oscilloscopes 20 GHz -100 GHz 14-bit 10 MS/s 10 Mpts - 510 Mpts

WaveJet Touch Oscilloscopes

The WaveJet Touch provides the performance, features, and touch screen user interface to simplify operation and shorten debug time. The compact design features a 7.5” touch screen, providing the convenience of touch operation in a portable design. With up to 5 Mpts of memory and 2 GS/s, every detail of the waveform can be captured and easily measured. The all-inclusive WaveJet Touch delivers maximum value for minimum investment.


Learn more Sales Enquiry

WaveSurfer 3000 Oscilloscopes

WaveSurfer 3000 oscilloscopes feature an advanced user interface with touch screen simplicity providing quick access to time saving debug tools. Feature the MAUI advanced user interface with touch screen simplicity to shorten debug time. Quickly identify and isolate anomalies with WaveScan, Fast Display, and History mode for faster troubleshooting, LabNotebook enables easy documentation and convenient collaboration. The advanced probe interface, upgradable bandwidth and multi-instrument capabilities provide maximum versatility and investment protection.


Learn more Sales Enquiry

WaveSurfer 10 Oscilloscope

The WaveSurfer 10 combines the MAUI advanced user interface with powerful waveform processing, in addition to advanced math, measurement and debug tools, to quickly analyze and find the root cause of problems. With a 10.4” touch screen display, high performance hardware, and compact form factor, the WaveSurfer 10 is unique among 1 GHz oscilloscopes.


Learn more Sales Enquiry

HDO8000 High Definition Oscilloscopes

HDO8000 oscilloscopes have eight analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high definition technology, and up to 1 GHz of bandwidth. They are ideal for debug and troubleshooting of high power three-phase power electronics, automotive electronics, and deeply embedded or mechatronic designs. Comprehensive digital logic (MSO), low-speed serial data trigger, decode and analysis toolsets, and the widest variety of probes and application packages complete the solution. Get the most intuitive long-memory analysis using the unique Q-Scape multi-tab display architecture.


Learn more Sales Enquiry

Motor Drive Power Analysis Software

Motor Drive Power Analysis software for Teledyne LeCroy HDO8000 high definition, mixed signal oscilloscopes (8 analog channels with 12-bit resolution) provides three-phase numerical and waveform power analysis from motor drive input through motor mechanical output. Included are real, apparent, and reactive power measurements, power factor and phase angle, efficiency, and various voltage and current parameters. Both two-wattmeter and three-wattmeter methods are supported, as well as line-line to line-neutral voltage conversion. Motor speed, position, and torque integration are the most complete available.

Learn more Sales Enquiry

LabMaster 10-100Zi 100 GHz Oscilloscope

100 GHz Bandwidth240 GS/s Real-Time Sampling Rate

The LabMaster10-100Zi real-time oscilloscope boasts the world’s highest bandwidth and fastest sampling rate. This world-leading performance is key to analyzing and understanding the fastest phenomena found in R&D labs where engineers and scientists are working on next-generation communication systems, high-bandwidth electrical components, and fundamental scientific research.


Learn more Sales Enquiry

WaveAce 1000 and 2000 Oscilloscopes:

The WaveAce combines long memory, wide screen display, extensive measurement capabilities, advanced triggering and great connectivity to improve trouble shooting and shorten debug time. With bandwidths from 40 MHz to 300 MHz, sample rates up to 2 GS/sand waveform memory up to 1 Mpts/Ch (2 Mpts interleaved) the WaveAce exceeds all expectations of a small affordable oscilloscope.


Learn more Sales Enquiry

WaveAce 100 and 200 Oscilloscopes

A good oscilloscope should simplify how you work and shorten the time it takes to find and debug problems. The WaveAce™ combines long memory, a color display, extensive measurement capabilities, advanced triggering and excellent connectivity to improve troubleshooting and shorten debug time. With bandwidths from 40 MHz to 200 MHz, sample rates up to 2 GS/s and waveform memory up to 10 kpts/Ch (20 kpts interleaved) the WaveAce exceeds all expectations of a small affordable oscilloscope.


Learn more Sales Enquiry

WaveJet 300A Oscilloscopes:

The WaveJet 300A provides specifications, feature set and user interface that simplify engineers work and shorten debug time. With a big ,bright 7.5” display, long KPts/Ch Memory , sampling speed up to 2GS/s will capture easily and show every detail of waveform. This series of oscilloscope falls in lower budget category.


Learn more Sales Enquiry

WaveSurfer MXs-B and MSO MXs-B Oscilloscopes

The WaveSurfer® MXs-B and MSO MXs-B oscilloscopes pack high performance hardware, powerful waveform processing and advanced math, measurement and debug tools into a compact form factor with a large touch screen display and intuitive user interface. With up to 10 GS/s sample rate and 32 Mpts of memory. WaveSurfer can capture large amounts of data at very high sample rates. The MSO MXs-B has 18 digital channels, can capture digital signals of up to 250 MHz. The MSO MXs-B offer analog and digital cross-triggering plus measurement tools to help debug digital buses.


Learn more Sales Enquiry

HDO4000 / HDO4000-MS High Definition Oscilloscopes

HDO 6000 Series oscilloscopes has HD4096 high definition 12-bit technology, with long memory, a compact form factor, 12.1” touch screen display, powerful measurement and analysis tools, and mixed signal capability. The HDO6000 is the ideal oscilloscope for circuit validation, system debug and waveform analysis. The powerful feature set provides analytical tools and unique application packages to streamline the testing process. HDO6000-MS High Definition mixed signal oscilloscope combines the high definition analog channels of the HDO6000 with the flexibility of 16 digital inputs. In addition, the many triggering and decoding options turn the HDO6000-MS into an all-in-one analog, digital, serial debug machine. HD4096 high definition technology consists of high sample rate 12-bit ADCs, high signal-to-noise ratio amplifiers and low-noise system architecture. This technology enables high definition oscilloscopes to capture and display signals of up to 1 GHz with high sample rate and 16 times more resolution than other oscilloscopes.


Learn more Sales Enquiry

VBA Xi-A Vehicle Bus Analyzers

The Vehicle Bus Analyzer is the first conventional oscilloscope to display both the full range of CAN protocol stack information-symbolic, hex, and electrical signal and to view additional in-circuit electrical signals (sensors and actuators, voltage levels, transients, etc.) that influence the CAN


Learn more Sales Enquiry

WaveRunner Xi-A / MXi-A Oscilloscopes

The Teledyne LeCroy WaveRunner Xi-A is the most powerful and capable scope available in its class. Basic system validation using advanced triggers, fast viewing modes, measurement parameters, or serial decodes is made simple and easy. Advanced debug, multi-domain analysis, and wave shape analysis are possible with tools unique to WaveRunner Xi-A.


Learn more Sales Enquiry

WaveRunner 6 Zi Oscilloscopes

WaveRunner 6 Zi oscilloscope has got unbelievable performance, is the most versatile scope in the 400 MHz to 4 GHz class. The performance indicators are deep memory and high sampling rate of 40 GS/s. The WaveRunner HRO 6Zi defines the best in class noise performance with a 12 bit ADC to provide the best resolution. The HRO 6Zi also features deep memory options up to 256 Mpts/Ch. The toolset provides every necessity for an engineer to validate a design, debug errors during board bring up, and offer powerful analysis to characterize an embedded system


Learn more Sales Enquiry

HDO6000 / HDO6000-MS High Definition Oscilloscopes

Combining Teledyne LeCroy’s HD4096 high definition 12-bit technology, with long memory, a compact form factor, 12.1” touch screen display and powerful measurement and analysis tools, the HDO6000 is the ideal oscilloscope for circuit validation, system debug and waveform analysis. The powerful feature set provides analytical tools and unique application packages to streamline the testing process. Tools such as WaveScan, Search and Find and History Mode, combined with advanced triggering, identify and isolate problems easily.


Learn more Sales Enquiry

HDO8000 High Definition Oscilloscopes

HDO8000 High Definition oscilloscopes have eight analog input channels, 12-bit resolution using Teledyne LeCroy’s HD4096 high definition technology, and up to 1 GHz of bandwidth. They are ideal for debug and troubleshooting of high power three-phase power electronics, automotive electronics, and embedded or mechatronic designs with high resolution sensor signals. Comprehensive digital logic (MSO) , low speed serial data trigger, decode and analysis tool sets and the widest variety of probes and application packages complete the solution.


Learn more Sales Enquiry

HRO 12-bit Oscilloscopes

The HRO™ 12-bit features an industry leading 12-bit Analog to Digital Convertor (ADC),deep memory of 256 Mpts/Ch, and superior DC accuracy specifications. These features are in addition to the extensive analysis features of the WaveRunner 6Zi.


Learn more Sales Enquiry

DDA 7 Zi-A Disk Drive Analyzers

Based on the WavePro 7 Zi-A Series models, the DDA7 Zi-A Series Disk Drive Analyzers are available in 3.5 and 6 GHz models and come equipped with 20Mpts/Ch acquisition memory. Dedicated disk drive measurements, trigger and zooming for failure analysis, and serial data measurement capability with a Disk Drive .Analyzer user interface are also standard to address high capacity disk drive designs. Operate in either DDA or SDA mode to analyze the serial data links or the physical media behavior on a hard drive.


Learn more Sales Enquiry

SDA 7 Zi-A Serial Data Analyzers

Combining signal fidelity with an architecture that maximizes speed in every performance aspect, the SDA 7 Zi-A Series presents a totally new oscilloscope experience from 1.5 to 6 GHz bandwidths. SDA models include standard serial data analysis capabilities for eye analysis and jitter decomposition. Experience the new X-Stream II architecture that provides 10 to 20 times faster long memory performance than any other oscilloscope. Combined with TeledyneLeCroy's flexible and deep analysis toolbox, the SDA 7 Zi-A Series gives an unforgettable experience for the debugging, validation, analysis and compliance testing of electronic designs.


Learn more Sales Enquiry

WavePro 7 Zi-A Oscilloscopes

Combining signal fidelity with an architecture that maximizes speed in every performance aspect, the new WavePro 7 Zi-A Series presents a totally new oscilloscope experience from 1.5 to 6 GHz bandwidths. Experience 50 ohm and 1Mohm inputs for every channel and four inputs into high-speed front end amplifiers and analog to digital converters. Experience the new X-Stream II architecture that provides 10 to 20 times faster long memory performance than any other oscilloscope. Combined with Teledyne LeCroy’s flexible and deep analysis toolbox, the WavePro 7 Zi-A Series gives an unforgettable experience for the debugging, validation, analysis and compliance testing of electronic designs..


Learn more Sales Enquiry

DDA 8 Zi-A Disk Drive Analyzers

DDA 8 Zi-A models combine all the attributes of WaveMaster 8 Zi-A with additional capabilities specifically suited for disk drive and serial data testing.


Learn more Sales Enquiry

SDA 8 Zi-A Serial Data Analyzers

SDA 8 Zi-A Serial Data Analyzers combine the highest bandwidth (45 GHz) and sample rate (120 GS/s) with superior performance at 20 GHz on all four input channels. Models are available from 4 to 45 GHz with complete bandwidth upgradability throughout the range. SDA 8 Zi-A models combine all the attributes of the WaveMaster 8 Zi-A series oscilloscopes with additional capabilities specifically suited for serial data testing, including the SDAIII serial data analysis package for eye and jitter measurements. Upgrade to SDAIII-CompleteLinQ to analyze up to four lanes, simultaneously..


Learn more Sales Enquiry

WaveMaster 8 Zi-A Oscilloscopes

WaveMaster 8 Zi-A combines the highest bandwidth (45 GHz) and sample rate (120 GS/s) with superior signal fidelity performance and 20 GHz on all four input channels. Models are available from 4 to 45 GHz with complete bandwidth upgradability throughout the range. The X-Stream II architecture maximizes speed in all aspects and provides for full analysis on maximum record lengths using Teledyne LeCroy's flexible and deep analysis toolbox.


Learn more Sales Enquiry

LabMaster 9 Zi-A Oscilloscopes

The LabMaster 9 Zi-A builds on the acquisition and analysis excellence of the Teledyne LeCroy WaveMaster 8 Zi-A oscilloscopes, but uses a modular design to provide massive numbers of channels (up to 80 channels at up to 20 GHz), up to five channels at 45 GHz, or something in between. Maximum sample rate is 120 GS/s with maximum analysis memory of 768 Mpts/Ch. LabMaster 9 Zi-A oscilloscopes have pioneered next-generation research and development in optical transmission, high speed SERDES, and multi-lane serial data


Learn more Sales Enquiry

LabMaster 10 Zi Oscilloscopes

LabMaster 10 Zi is the world's highest bandwidth real-time oscilloscope - 65 GHz at 160 GS/s. LabMaster 10 Zi is also modular - it breaks channel count barriers and provides more "bandwidth density". The modular design provides the simplest upgrade path in bandwidth and channel count, with one acquisition module providing four channels at 36 GHz or two channels at 65 GHz, with capability for up to 20 acquisition modules


Learn more Sales Enquiry

WaveExpert Sampling Oscilloscopes

The ideal signal integrity analysis solution for high-speed links. Measurement complexity and the emergence of receiver equalization which allows high-speed serial data links to operate error-free even when the signal is severely distorted requires WaveExpert's high bandwidth and detailed analysis capability


Learn more Sales Enquiry